AMETEK Programmable Power MX / RS Series SCPI Programming Manual
12 MX / RS Series
the IEEE-488 address programmatically since the next statement sent to the source must
reflect the new address.
1.4.2
USB Capabilities of the AC source
All AC source functions are programmable over the USB interface. The USB capabilities of
the AC source are listed in Chapter 2 of the User's Manual. Some capabilities support on
the GPIB interface such as ATN, GET and SRQ interrupts do not apply to the USB interface.
The USB interface operates internally at a fixed baudrate of 460800 baud but USB 2.0 burst
transfer rates are supported.
To set up the USB interface on a Windows XP PC, refer to section 3.4, “USB Interface”.
The USB interface may be used to install updated firmware for the controller if needed.
Firmware updates and a Flash Loader utility program and instructions are available from the
AMETEK Programmable Power website for this purpose. (
www.programmablepower.com )
Multiple USB connections to same PC:
The Windows driver used to interface to the power source’s USB port emulates a serial com
port. This virtual com port driver is unable to reliable differentiate between multiple units
however so the use of more than one AC power source connected to the same PC via USB
is not recommended. Use of the GPIB interface is recommended for these situations.
1.4.3
LAN Capabilities of the AC source
All AC source functions are programmable over the LAN (Ethernet) interface if the –LAN
option is installed. The LAN capabilities of the AC source are listed in Chapter 2 of the
User's Manual. Some capabilities support on the GPIB interface such as ATN, GET and
SRQ interrupts do not apply to the LAN interface. The LAN interface operates internally at a
fixed baudrate of 460800 baud but autodetection of 10Base-T, 100Base-T and 1000Base-T
is supported.
To set up the LAN interface on a Windows XP PC, refer to section 3.5, “LAN Interface
Option”.
1.4.4
RS232C Capabilities of the AC source
All AC source functions are programmable over the RS232C interface. The RS232C
capabilities of the AC source are listed in Chapter 2 of the User's Manual. Some capabilities
support on the GPIB interface such as ATN, GET and SRQ interrupts do not apply to the
RS232C interface. Baudrates from 9600 to 115200 are supported on units that have both
USB and RS232. For units with only RS232, the maximum baudrate is 38400.
To set up the RS232C interface, refer to section 3.3, “RS232C Interface”.
The RS232C interface may be used to install updated firmware for the controller if needed.
Firmware updates and a Flash Loader utility program and instructions are available from the
AMETEK Programmable Power website for this purpose. (
www.programmablepower.com )