California Instruments 801RP Series Instrukcja Użytkownika Strona 191

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 223
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 190
MX / RS Series SCPI Programming Manual AMETEK Programmable Power
MX / RS Series 191
DO160:EMERgency:VOLT_FREQ:MAXimum
This command will set the voltage and frequency to the maximum level for the emergency
operation.
Command Syntax DO160: EMERgencyl:VOLT_FREQ: MAXimum
Parameters none
Examples DO160: EMER:VOLT_FREQ:MAX
Query Syntax none
DO160: EMERgency:VOLTage:UNBalance
This command will unbalance the voltage level for each phase to the emergency high and
low operating voltage of each phase. This test is valid only for three phase AC source.
Command Syntax DO160:EMERgency:VOLTage:UNBalance
Parameters none
Examples DO160: EMER:VOLT:UNB
Query Syntax none
DO160:ABNormal:VOLTage:MINimum
This command will set the voltage to the minimum level for the abnormal operation.
Command Syntax DO160:ABNormal:VOLTage:MINimum
Parameters none
Examples DO160:ABN:VOLT:MIN
Query Syntax none
DO160:ABNormal:VOLTage:MAXimum
This command will set the voltage to the maximum level for the abnormal operation.
Command Syntax DO160:ABNormal:VOLTage:MAXimum
Parameters none
Examples DO160:ABN:VOLT:MAX
Query Syntax none
DO160:ABNormal:VOLTage:UNDer
This command will set the voltage to the under voltage level for the abnormal operation.
Command Syntax DO160:ABNormal:VOLTage:UNDer
Parameters none
Examples DO160:ABN:VOLT:UND
Query Syntax none
Przeglądanie stron 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 222 223

Komentarze do niniejszej Instrukcji

Brak uwag