California Instruments 801RP Series Instrukcja Użytkownika Strona 82

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 223
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 81
AMETEK Programmable Power MX / RS Series SCPI Programming Manual
82 MX / RS Series
FREQuency:SLEW:TRIGgered
This command sets the rate at which frequency changes during a triggered output transient.
Instantaneous frequency changes can be obtained by sending MAXimum.
Command Syntax [SOURce:]FREQuency:SLEW:TRIGgered <NRf+>
Parameters 0.01 to 1E9MAXimum
Unit Hz (Hertz per second)
*RST Value MAXimum
Examples FREQ:SLEW:TRIG 75 FREQ:SLEW:TRIG MAX
Query Syntax [SOURce:]FREQuency:SLEW:TRIG?
Returned Parameters <NRf>
Related Commands FREQ:SLEW:MODE FREQ
FREQuency:TRIGgered
This command programs the frequency that the output will be set to during a triggered step
or pulse transient.
Command Syntax [SOURce:]FREQuency:TRIGgered <NRf+>
Parameters 0 to maximum frequency range specified by the LIMit:FREQuency
command
Unit Hz (Hertz)
*RST Value 60 Hz
Example FREQ:TRIG 50
Query Syntax [SOURce:]FREQuency:TRIGgered?
Returned Parameters <NR2>
Related Commands FREQ FREQ:MODE
Przeglądanie stron 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 222 223

Komentarze do niniejszej Instrukcji

Brak uwag